Product

This present form, or for the products mentioned, mandatory technical characteristics under the Ecodesign Directive No. 1254/2014 / EU

  GALBE     CUBE   URBANMAXI 
 Name of supplier VENTILAIRSECVENTILAIRSEC VENTILAIRSEC  VENTILAIRSECVENTILAIRSEC VENTILAIRSEC VENTILAIRSEC VENTILAIRSEC VENTILAIRSEC VENTILAIRSEC 
Model designationESSENTIELLEPRESTIGE 2  PRESTIGE 2+ CAVE 2ESSENTIELLEPRESTIGE 2 PRESTIGE 2+ ESSENTIELLEPRESTIGE 2 MAXI 
 energy rating C C  C F C   C  C  C  C B
ERP labelsico-pdfico-pdfico-pdfico-pdfico-pdfico-pdfico-pdfico-pdfico-pdfico-pdf
average climate SEC – specific energy consumption (kWh / (m2 year) -24,1 -24,1 -23,4 -6,8 -24,4 -24,5-24,2  -26,9 -26,9 -23,1
cold climate SEC – specific energy consumption (kWh / (m2 year) -51,2-51,2  -50,4 -23,2 -51,5 -51,5-51,2  -54 -54-53,6 
warm climate SEC – specific energy consumption (kWh / (m2 year) -8,6-8,6 -7,9 2,6  -8,9-9 -8,7 -11,4 -11,4-11,1 
Flow typeSF  SFSF SF SF SF SF SF SF SF
 declared typologyUVR UVR UVR UVR  UVR UVRUVRUVR UVRUVR
 Type of engine installed or plannedvariable speedvariable speedvariable speed multispeedvariable speed variable speedvariable speedvariable speed variable speed variable speed
 Type heat recovery system na nana na na nana na  na na
 Thermal efficiency heat recovery (in%) nana na na na nana  na na na
Maximum flow of URV (m3 / h) 153,6 162,7150,6 148,7 170,3 177 160 185,6 185,6386,7 
 Power consumption in Qmax (W) 58,358,7  59,2 62,060 60,3  58,922,2  22,266,5 
LWA Sound pressure level (dB (A)) 41 414352 414143 515149
reference flow (m3 / s) 0,033 0,034 0,029 0,0540,037  0,0390,035 0,029 0,028 0,098 
 reference pressure (Pa) 50,8 50,350,8  50,1 50,5 49,849,9 50,5 50,1 49,8 
SPI (en kW/m3/h) 0,00032 0,00032  0,00037 0,00033 0,000290,00029 0,00031 0,00010 0,00010 0,00013
 CTRL control factor (in%) 0,65 0,65 0,6510,65  0,650,65  0,65 0,650,65 
Control TypeLocal modulated regulation Local modulated regulationLocal modulated regulationmanual controlLocal modulated regulationLocal modulated regulationLocal modulated regulationLocal modulated regulation Local modulated regulation Local modulated regulation
 maximum external leakage rate in depression (in%) 22,622,6 22,6 32,6  32,612,7 12,7  12,3 12,3 4,7
 Maximum external pressure leak rate (in%)21,7 21,7  21,730,2 30,2 11,9 11,9 14 14 4,8
 maximum internal leak rate in depression (in%) na nana nanana na nana na 
maximum internal leak rate pressure (in%) na na na na na na na na nana 
Info Filter warning CF. notice  CF. notice  CF. notice CF. notice  CF. notice   CF. notice CF. notice  CF. notice  CF. notice  CF. notice 
regular replacement of filters for the performance and efficiency of the unit
 
 CF. notice  CF. notice  CF. notice CF. notice  CF. notice   CF. notice  CF. notice CF. notice  CF. notice  CF. notice 
Installation instructions ventilation grilles CF. notice  CF. notice  CF. notice  CF. notice CF. notice   CF. notice  CF. notice  CF. notice CF. notice  CF. notice 
Pre assembly / disassembly instruction (internet) CF. notice  CF. notice  CF. notice  CF. notice CF. notice   CF. notice  CF. notice  CF. notice CF. notice  CF. notice 
Sensitivity of the airflow to the pressure variations to + 20 Pa  na  na  na na na  na  na  na   na na 
Sensitivity of the airflow to the pressure variations to 20 Pa  na  na  na  na  na  na  na  na na   na
Air tightness indoor / outdoor (m3 / h)  na  na   na  na  na  na  na  na  na  na
 Conso Annual KWh / year electric 1,681,69  1,98 4,131,55 1,53  1,650,55 0,55 0,69
average climate – EAC annual heating Economy (kWh primary energy / year) 28,3028,30  28,3017,15  28,3028,30 28,30 28,30  28,3028,30 
cold climate – EAC annual heating Economy (kWh primary energy / year)  55,36 55,36 55,3633,55   55,36  55,36 55,36   55,36  55,36 55,36 
warm climate – EAC annual heating Economy (kWh primary energy / year)12,80  12,8012,80 7,76  12,80 12,8012,80  12,8012,80 12,80